G Series - Analog Dosing Pump

Metering Pumps "G" Series are the ideal solution for low / middle dosing of chemicals. All control and setup parameters are available through knobs and a visual system (led). Metering Pumps "G" Series have got an On/Off digital switch for ensure dosing activity (available only for some models).

Flow rate is determined by the stroke length and by the stroke speed. The stroke length is adjustable from 0 to 100% using the stroke length adjustment knob. However dosing accuracy is guarantee within an adjustment range from 30% to 100%. The led on the frontal panel shows the activity status of the pump.

Specifications

Pump Strokes 0 to 150 injections per minute
Suction Height 1.5 Meters
Environment Temperature 0 to 45°C (32° to 113°F)
Chemical Temperature 0 to 50°C (32° to 122°F)
Installation Class II
Pollution Level 2
Audible Noise 74 dbA
Packaging and Transporting Temperature -10°C to 50°C