HMS DC - Dosing Pump

Metering Pumps "HMS DC" Series are the ideal solution for low / middle dosing of chemicals. All control and setup parameters are available through a digital keyboard and they are displayed on a LCD backlit display. Pump has: "Standby" input, "Level" input and "Alarm" (contact)output.

Flow rate is determined by the stroke length and by the stroke speed. The stroke length is adjustable from 0 to 100% using the stroke length adjustment knob. However dosing accuracy is guarantee within an adjustment range from 30% to 100%.

Stroke Mode: Pump doses at a constant rate set in "SPH" (strokes for hour), "SPM" (strokes for minute) parameters set during program session.

Specifications

Pump Strokes 0 to 150; 0 to 120 injections per minute
Suction Height 1.5 Meters
Environment Temperature 0 to 45°C (32° to 113°F)
Chemical Temperature 0 to 50°C (32° to 122°F)
Installation Class II
Pollution Level 2
Audible Noise 74 dbA
Packaging and Transporting Temperature -10°C to 50°C