Multi-Channel Controllers for Water Quality Monitoring

The MC 6587 and MC 7687 multi-channel controllers can each monitor up to three digital sensors, giving MC controllers the ability to provide control and alarming functions on a large combination of water quality parameters. If necessary, users can connect two or three sensors of the same type in order to have a double or triple validation.

The MC 6587 is furnished in its own wall-mounted IP66 enclosure while the MC7687 is equipped with an IP65 front panel and is designed to be mounted in a larger IP65 (or better) enclosure. Both MC controllers may be powered by a wide range of AC voltages and a 24 volt DC powered version is also available.

Request a Quote Now
Download full spec sheet
reverse osmosis monitoring and control
AVAILABLE PARAMETERS:
  • Turbidity and suspended solids
  • Dissolved oxygen
  • Conductivity (high ranges)
  • Free chlorine
  • Chlorine dioxide
  • Dissolved ozone
  • Temperature ​
EACH INSTRUMENT PROVIDES:
  • Display of the monitored values from the connected sensors
  • Automatic control functions (including PID) based on monitored values
  • Alarm from the min/max values of the monitored values
  • Programmable dual analog output for recording and acquisition of the monitored values or PID control
  • RS485/ Modbus (Function Codes 03, 06, 16) 
  • Hold/alarm function activated by two external dry contacts
  • Automatic/manual autoclean function
APPLICATIONS
The MC 6587 and MC 7687 are an excellent choice for a number of applications, including:
  • Reverse Osmosis (RO) Pretreatment Systems: The MC products are an excellent choice for monitoring the equipment and treatment processes used for pretreating reverse osmosis feed water. The MC products' ability to monitor multiple parameters such as turbidity, free chlorine, temperature, and others allows the precise control of the pretreatment system to insure low life and dependable performance from any RO system. 
  • Filtration Systems: The ability to monitor feed turbidity, filtrate turbidity, and backwash turbidity (suspended solids) with a single instrument makes the MC products an excellent choice for monitoring and control filtration systems of all types. This includes conventional media filtration as well as high performance membrane filtration systems. Other filtration applications include monitoring free chlorine before and after carbon filters. Another involves monitoring turbidity before and after iron removal (greensand) filters together with monitoring oxidizer concentration in the the filtrate. 
  • Membrane Bioreactors (MBRs): For MBR applications, the MC products can be used to monitor dissolved oxygen in the bioreactor while monitoring turbidity after the membrane filters. Another MBR option is the ability to monitor multiple dissolved oxygen values at various points in the bioreactor. 
  • Cooling Water: For cooling water applications, the MC products allow the simultaneous monitoring of oxidizers, turbidity, and conductivity. 
  • Other Applications: Due to their ability to monitor multiple parameters coupled with the long list of available sensors, the MC controllers represent a great value for any water treatment application.​
SPECIFICATIONS:
  • Display: multi-line graphic
  • Input from: Multiple digital sensors (see DIGITAL SENSORS)
  • Selectable scales 
  • Two set-point with min/max function, hysteresys and delay time programmable for every parameter
  • Min/max alarm relay, activate/deactivate function selectable 
  • Two analog outputs: 0-20 or 4-20 mA isolated for PID control or measurement transmission 
  • RS485/ Modbus (Function Codes 03, 06, 16) 
  • Settings configuration on two levels with access code selected by the operator 
  • Two digital inputs for hold or alarm function, selectable
  • Power supply: 85/264 Vac - 50/60 Hz,  5 VA ​(DC version also available)
Picture
MC 6587 Specifications and Options:
  • Enclosure: IP 66
  • Dimensions: 256 x 230 x 89 mm
  • Registered design: 002564666-002
  • 091.428   Power supply 9/36 Vdc - 24 Vac
Picture
MC 7687 Specifications and Options:
  • Enclosure: metallic, IP 65 frontal protection
  • Dimensions: 98x98x104 mm (90x90x95 mm back)
  • Registered design: 002564666-003
  • 091.427   Power supply 9/36 Vdc - 24 Vac
DIGITAL SENSORS:
  • C 8825.4: toroidal conductivity probe, submersible/in line, PVC-C 
  • C 8325.5: toroidal conductivity probe, submersible, PVDF
  • C 8520.5: toroidal conductivity probe, tapered collar DN 32, PVDF
  • CL 7901: free chlorine sensor
  • CL 7902: combined chlorine sensor
  • OZ 7901: dissolved ozone sensor
  • CL 3436: transmitter for CL 7901, CL 7902, and OZ 7901
  • OD 8325: submersible optical dissolved oxygen probe, PVC-C 
  • OD 8525: side-stream and in-line optical dissolved oxygen probe, PVC-C 
  • TU 8325: submersible turbidity probe, PVC-C 
  • TU 8355: submersible turbidity/suspended solids probe, PVC-C 
  • TU 8525: side-stream and in-line turbidity probe, PVC-C
  • TU 8525.5: side-stream and in-line turbidity probe, PVDF
  • TU 8555: side-stream and in-line turbidity/suspended solids probe, PVC-C 
  • TU 8555.5: side-stream and in-line turbidity/suspended solids probe, PVDF 
Request a Quote Now

Contact Us

(505) 334-5865
RODI Systems Corporation
936 Highway 516, Aztec, NM 87410
[email protected]
Social Media

Search this site

Read our Terms and Conditions.
  • Home
  • Products
    • RODI Products
    • Ceramic Membrane
    • Chemical Feed Systems
    • Controllers & Instruments
    • Custom Controllers
    • Desalination Systems
    • High Purity Systems
    • Silt Density Monitors
    • Wastewater Treatment Systems
    • Water Purification Systems
    • Water Treatment for Hydrogen Production
  • About Us
    • About RODI
    • RODI Projects
    • RODI Customers
    • Industries
    • Technologies
  • Get Support
    • Technical Support
    • How To Buy Standard Products
  • Contact RODI
  • Resources
    • How Does Reverse Osmosis Work?
    • What is Desalination?
  • Blog